Brand Name : Rainbow
Model Number : PM-9000GTE
Certification : ISO13485
Place of Origin : China
MOQ : 1 unit
Price : US $395-580/unit
Payment Terms : L/C, T/T, Western Union, MoneyGram
Supply Ability : 30000units/year
Delivery Time : Within 3 days
Packaging Details : Anti-collision film+ Carton box Carton box dimension: 41*29.5*38cm Gross weight: 5.85kg
Properties : Diagnosis & Injection
Product name : cheap veterinary patient monitor
display size : 15'' LCD
ECG : 3/5 lead
graphic trends and date storage : 720-hour
English Talking function : Yes
Option : Printer,Anesthetic gas module,Etco2,IBP
This monitor is suitable for felines, canines and other animals, may monitor the physical parameters, such as electrocardiograph (ECG), noninvasive blood pressure (NIBP), oxygen saturation (SpO:), respiration rate (Resp), body temperature (Temp) and so on, can display maximum 8 waveforms and all information of the parameters monitored in the same screen.
Features
Parameters
Power Supply | 100~240VAC,50/60Hz,Pmax=90VAFuseT1.5A |
Battery | 2.6 Ah 12V rechargeable battery Operating time after full charge is more than 1 hours Operating time after the first alarm of low battery will be about 5 minutes Maximum charging time is less than 6 hours. |
Signal Interface | Network interface standard RJ45 Socket |
Storage | Trend 720 hours NIBP review 1000 NIBP events Wave review 2 hours Alarm review 200 alarm events All storage data are non volatile. |
ECG | Lead mode 5 Leads: RA. LA, LL, RL. V; lead mode: I, II, III, AVR, AVL, AVF, V Gain ×2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV Sensitivity >200 μ VP-P Differential Input Impedance >5 M ohm Bandwidth Surgery 1~20Hz CMRR Diagnostic Mode >90dB |
Respiration | Method R-F(RA-LL) Impedance Differential Input Impedance >2.5 MΩ Measuring Impedance Range 0.3~5.0Ω Baseline Impedance Range 100Ω– 2500Ω Bandwidth 0.3 ~ 2.5 Hz |
NIBP | Method Oscillometry Mode Manual, Auto, continuous Measuring Interval in AUTO Mode 1 /2 /3 /4 /5/ 10/ 15/ 30 /60 /90/120/240/480/960 Min Measuring Period in Continuous Mode 5 Min Measuring and Alarm Range 10~270mmHg Alarm Type SYS, DIA, MEAN |
SpO₂ | Measuring Range 0 ~ 100 % Alarm Range 0 ~ 100 % Resolution 1 % Accuracy 70% ~ 100% ±2% 0% ~ 69% unspecified |
Temperature | Channel 2 Measure and Alarm Range 0~50℃ Resolution 0.1℃ Accuracy(nosensor) ±0.1℃(0℃–50℃) |
If you need more details, please do not to contact us now!
![]() |